Reading input file... Opening log file otfsched.inp Using an observing frequency of 100000 MHz Nyquist spacing is 14.1 arcsec Using j2000 as the coordinate system Longitude and latitude: 336.0000, -5.0000 Map width in degrees: 0.200 Nyquist scanrate in arcsec/sec: 3.5 Row spacing in arcsec: 10 Actual width of map is 12.2 arcmin Number of rows per map is 73 Number of cycles per row is 104 Scan rate (arcsec / sec) is 3.51 Number of OFFs per map is 73 Time (sec) for OFF scans is 28.9 Number of cycles per OFF is 15 Time to complete one map is 332 minutes 0 lines written to otfsched.inp. Total time elapsed is 343 mins Schedule written to mopraotf_Mas.sch