![]() |
|
abph[ase] #1 #2Set the desired phase (in degrees) to insert between the A and B polarisations of each
antenna. The phase will not be inserted however until a pcal a command is
issued.
The most useful purpose for this command is to switch between linear
polarisation (for which #1 and #2 are both 0) and circular
polarisation, which requires a phase shift of \pm90^{\circ} between the
linear feeds. This is most commonly used for VLBI experiments and NASA tracking,
which record circular polarisation. Example:
abph -90 -90
This command will produce circular polarisation output from the tied array units,
for all bands except 20/13cm.
Related commands: pcal, catie pol
acal #1 #2 [a]Tells the correlator that the current amplitude at the centre of the
tvchannel range is #1 in IF1, and #2 in IF2. The
correlator uses this information when calculating the system temperature
that it writes into the RPFITS files. If the command is given with
the trailing a modifier, then the correlator will apply the calibration.
Related commands: dcal, pcal, tvchannels, reset acal, calband
att{1,2} ca0n #1 #2Set the CABB attenuators on IF1 (att1) or IF2 (att2), antenna
n to #1 for polarisation A and #2 for polarisation B.
The current CABB attenuator settings are shown in the “Sampler Levels” tab in
the data panel.
There is an automatic attenuator servoing command for doing this rapidly without
user intervention, called atts.
Related commands: atts
atts[ervo] [{on,off}]Attenuator servoing will make the correlator attempt to bring the sampler/GTP
statistics into line with the target that was set with tatts. It does
this by adding or removing attenuation on a per-antenna, per-polarisation,
per-IF basis. It may take a relatively large number of cycles (more than 5)
to accomplish this, and may not be able to precisely meet the target specified.
Without arguments, this command returns the current state of the attenuator
servoing mechanism (which can also be found in the status panel). To start/stop
the servoing mechanism, issue this command with the on/off
argument respectively.
It is important to check the resultant attenuation levels (shown on the
“Sampler Levels” tab in the data panel) for potential problems during
this process.
Related commands: tatts, userms, usegtp, atts
calband [#1 #2]This command changes the IFs that the correlator uses to determine the
delays, phases and amplitudes. In normal observing with a configuration
that provides both 2 GHz continuum IFs (eg. CFB 1M-0.5k), these
quantities should be calculated from the continuum IFs. To ensure this,
#1 and #2 should both be set to 0:
calband 0 0
If the correlator configuration does not provide the 2 GHz continuum IFs (eg. cfb64_2f_zm1), then it is necessary to use the zoom bands to correct the delays and phases. In this case, for example, it would be necessary to issue the command:
calband 3 4
After this command, all the variables that normally apply to the continuum
bands (eg. tvchannels, dcal, pcal, acal, delavg) will now apply to
the first and second zoom bands respectively.
Related commands: acal, dcal, pcal, tvchannels, abphase, delavg, tatts, atts
calf[req] [{1,2}]Specify the IF to use when manually correcting the delay with the
doffset command. Without arguments, this command will return the
currently selected IF.
Related commands: calpol, doffset
calp[ol] [{a,b}]Specify the polarisation to use when manually correcting the delay with
the doffset command. Without arguments, this command will return
the currently selected polarisation.
Related commands: calfreq, doffset
calrefant [ca0n]Set the antenna to reference all other antenna against for calibration.
As with refant, this is usually best set to antenna 2, if it is
included in the array. If this command is issued without arguments, it
returns the current setting of this variable.
Related commands: refant
[ca]tieShows the current catie settings.
Related commands: catie reset, catie gain, catie pol.
[ca]tie array #1 #2Tie the output of antenna(s) # into the tied array output. Example:
tie array 123456 123456
This command would tie the signals from all the ATCA antennas together.
Related commands: catie reset, catie gain, catie pol.
[ca]tie pol {c,l} {c,l}Sets the output to have circular or linear polarisation for each IF. Example:
tie pol c c OR tie pol l l
Related commands: catie reset, catie gain, catie array.
[ca]tie gain {#1 #2,auto}Sets the gain for the tied array output for each IF. If all antennas are tied, a
gain of 0.1 is recommended. The gain can be set to change automatically by
specifying auto instead of the IF gains.
Related commands: catie reset, catie pol, catie array.
[ca]tie resetResets the output from the tied array output module in the correlator.
Related commands: catie gain, catie pol, catie array.
cf [#1 [#2]]Without arguments, this command prints the current setting of the CABB local oscillator for each continuum IF. With arguments, this command allows you to set the CABB local oscillator frequency (specified in MHz) for each continuum IF. The LOs can be set to frequencies between 4928 - 10928 MHz.
cfoffset [#1 #2]This command can be used to place the 64 MHz channels available in the
vlbi_64_64_tda and vlbi_64_1_tda configurations away from
the normal central frequency of the band. The #1 and #2
parameters can be one of -1,0,1, which shifts the central frequency
of the 64 MHz channel away from the central frequency listed in the schedule
by -512,0,512 channels respectively. Whether each shift corresponds to an
increase or decrease in real frequency is determined by the sideband of the
IF.
This is especially useful in the 20/13cm band, where the LO can only be tuned
down to a central frequency of \sim1750 MHz. To allow for the 64 MHz
VLBI channel to cover the neutral hydrogen frequencies, the central frequency
is specified as 1912 MHz (1400 + 512), and the cfoffset is set to
1 1 (as 20/13cm is lower-sideband). Note: this command must
be issued before the scan is started in the VLBI configurations.
Related commands: tvchannels
[no]czabsThis command enables (with czabs) or disables (with noczabs)
the correlator’s auto-correction and online application of the zoom bandpasses.
Since the zoom bands are digitally constructed, their bandpass shapes can be
accurately determined during the observation, and corrected before being
written out to the data file. Use this command to disable this behaviour,
as it is enabled by default.
dcal [a]Tells the correlator to estimate the delay in each of the first two IFs,
using the data in the tvchannels range, averaged by delavg channels
for the previous 3 cycles. If the a modifier is included, then the
correlator will apply the appropriate correction to bring the delay in
each IF back to 0.
Related commands: acal, pcal, tvchannels, delavg, calband, nncal, reset delay
delavg [#]Set the number of channels to average together within the tvchannels
range, in order to increase the accuracy of the delay determination
by the correlator. The correlator calculates the delay by attempting to
fit a straight line to the phase as a function of frequency across the
tvchannels. If the source is not very bright, then the signal-to-noise
ratio of the phase values will be small, and the delay fit will not be
well constrained. By increasing the delavg quantity, the number
of points used for the fit will decrease, but the amount of data
contributing into each point will increase, hence improving the signal-to-noise
ratio, and helping to constrain the fit.
This command is especially useful at higher frequencies, and is almost
necessary in the 3mm band, due to the lower sensitivity of that receiver.
Related commands: tvchannels, dcal
delcorr fnRecover the delay settings used for the current frequency configuration,
after the correlator has been reprogrammed. This is known to work when going
between the standard CFB 1M-0.5k configuration and any of
nasa_1_64_tda (NASA tracking), vlbi_64_64_tda and
vlbi_64_1_tda (VLBI). It works on a single IF at a time, and the
correlator should be allowed to settle for a few cycles after a reprogram
before this command is issued.
Related commands: dcal, pcal, abphase, cfoffset
delscan fN offset,incrStart the correlator scanning through additional delay offsets. Example:
delscan f1 -40 4
This command will make the correlator subtract 40ns of delay from each
antenna (except the reference antenna), and then add 4ns of delay per
subsequent cycle. By looking at the amplitudes at each cycle, it is then
possible to determine which offset is closest to the systemic delay for
each antenna. These offsets can be added into the correlator with the
doffset command. This command will continue to operate until
the nodelscan command is issued.
This command is not usually necessary during normal setup procedures.
Related commands: doffs, dcal, nodelscan
diginit {all,ca0n [{1,2}{a,b}]}Resets the digitisers out at the specified antennas. These digitisers can either be specified as:
allReset all digitisers.
ca0nResets all digitisers associated with antenna n.
ca0n {1,2}{a,b}Reset a single digitiser. Example:
diginit ca02 2b
This will reset only the digitiser associated with antenna 2, second IF, B polarisation.
This command is most appropriately used if the input shown in the “Data
Links” tab is coloured red, and an rtminit of that input has failed
to restore it. That is, it is generally advisable to attempt an rtminit
before attempting a diginit.
Related commands: rtmreset,rtminit
doffs[set] [ca0n=#]Allows for manual correction of delay offsets. Without arguments, this
command will print all the current delay offset numbers for the current IF
(selected by calfreq) and polarisation (selected by calpol).
This command allows for direct setting of these delay offsets. The reference antenna will always
have a delay offset of 0. A positive offset then means that the correlator will receive
the same wavefront from that antenna before the reference antenna, and a negative offset
means that the correlator will receive the same wavefront from that antenna after
the reference antenna. Example:
calf 1 calp b doffs ca01=-432
This command tells the correlator to expect the antenna 1, IF1, B polarisation signal 432 ns after that of the reference antenna. Note: this is not merely a function of geometric delay, but will also include the travel time along the cables from the antenna to the correlator, etc. It is therefore not easily apriori calculable by non-experts.
This command is most useful for rough correction of delay if the phase is
wrapping too quickly for the correlator to determine the appropriate delay
correction automatically with the dcal command. It is not usually
necessary for this command to be used.
Related commands: calfreq, calpol, dcal, delscan
f[un]flag f[N] [{#,#1-#2,default,birdies}] ...Flag (fflag) or unflag (funflag) the channel #, or
channel range #1-#2 from IFN. By flagging a channel, it no
longer contributes to the phase, delay or amplitude calculated by the
correlator, even if it lies within the tvchannels range. A flagged
channel also is written out to the RPFITS file as having precisely 0
amplitude, and has its flagged bit set. Example:
fflag f1 1187 2001
This command would flag out channels 1187 and 2001 from IF1. Example:
funflag f2 1800-1840
This command would unflag all channels between 1800 and 1840 inclusive.
There are two arguments – default and birdies – that flag
specific channels that are known to often or always be bad. For
default these channels are 513, 1025 and 1537. For birdies
these channels are 129, 157, 257, 641, 769, 1153, 1177, 1281, 1409, 1793
and 1921. The default argument is normally not required to be issued,
except when changing to the 64 MHz zoom modes. The birdies argument
is always recommended while using the CFB 1M-0.5k configuration.
Without arguments, this command returns the current number of unflagged
channels in both IFs, which should never be more than 2046 (2049 channels
total - 3 always flagged default channels).
Related commands: tvchannels
gpibConnect to the DTT Interface LO synthesizer required for NASA tracking. If the correlator hangs when this command is issued, it is possible that a hardware reset and power cycle of the GPIB box in the screened room is required.
nncal [#]This command changes the number of cycles the correlator uses to determine
the delays and phases to that specified as #. Normally, this number is
3 (cycles), but for NASA tracking, where self-calibration of the phases is
enabled, it is more accurate to only consider the latest cycle, so it is
usually set to 1 in this case. Issuing this command without an argument will
return the current setting.
Related commands: selfcal
nodelscanThis command stops the correlator from continuing the delay scanning
procedure that was started with the delscan command.
Related commands: delscan
pcal [a]Tells the correlator to estimate the phase in each of the first two IFs,
using the data in the tvchannels range, for the previous 3 cycles.
If the a modifier is included, then the correlator will apply the
appropriate correction to bring the phase in each IF back to 0.
Related commands: acal, dcal, tvchannels, calband, nncal, abphase
phoffs[et] [ca0n=#]Allows for manual correction of phase offsets. Without arguments, this
command will print all the current phase offset numbers for the current
IF (selected by calfreq) and polarisation (selected by calpol).
This command allows for direct setting of these phase offsets.
Example:
calf 1 calp b phoffs ca01=18
These commands tell the correlator to make the phase offset on antenna 1, IF1, B polarisation, 18 degrees.
This command is most useful for rough correction of phase. It is not usually
necessary for this command to be used.
Related commands: calfreq, calpol, pcal
refant [n]Set antenna ca0n as the
reference antenna. For most arrays and setups, CA02 is most useful as
the reference antenna. If the argument is not given, the current
reference antenna is displayed.
Related commands: calrefant
resetDO NOT ISSUE THIS COMMAND. THIS WILL CAUSE THE CORRELATOR GUI TO FAIL (REQUIRING A RESTART) AND THE UNIVERSE TO MORPH INTO A CATERPILLAR.
reset abdel[ay]Reset only the cross-polarisation delays.
Related commands: reset delays
reset acalReset the gain to amplitude scaling factors that are set after doing an
acal.
Related commands: acal
reset delaysReset the correlator delay offsets back to their geometric default. This
command can be useful if a dcal has apparently made the delay worse,
to the point that it has become very difficult or impossible for the
correlator to calculate the remaining delay.
Related commands: reset abdelay
rtminit {all,ca0n [{1,2}{a,b}]}Resets the “rapid transport module” (RTM) on the specified inputs. These inputs can either be specified as:
allReset all RTMs.
ca0nResets all RTMs associated with antenna n.
ca0n {1,2}{a,b}Reset a single RTM. Example:
rtminit ca02 2b
This will reset only the RTM associated with antenna 2, second IF, B polarisation.
This command is most appropriately used if the 1ms values for some
input(s) (shown in the “Data Links” tabs) are very much different from the
expected values.
Related commands: rtmreset,diginit
rtmr[eset]Reset the sync error counts in the “Data Links” tabs in the data panel.
This can be useful if the error counts are high, but it is not clear whether
they are continuing to increase. This command will immediately (ie. on the
next cycle) reset the counts to 0, so if any counts remain non-zero after
this command, errors are still present.
Related commands: rtminit, diginit
selfcal [{#1 #2,{on,off}}]The correlator is able to continuously adjust the phases on a cycle-by-cycle basis in order to keep them as close to zero as possible. This is only possible while observing a bright calibrator or spacecraft, and is only really useful for VLBI and NASA tracking.
The command format selfcal #1 #2 instructs the correlator to use
the phases determined from IF#1 to correct IF1, and the phases
determined from IF#2 to correct IF2. For NASA tracking, where IF1 is
configured to be 2 GHz, 2048 channels, and IF2 is configured to be 64 MHz,
1 channel, the appropriate selfcal command is:
selfcal 1 1
This is because the incoming phase of the signal coming in from a spacecraft (which will only be a few MHz wide) can not be determined from a single 64 MHz channel.
The command format selfcal {on,off} is used to enable or disable
the self-calibration process. Issuing the command without arguments will
return the current self-calibration state (which is also shown in the
status panel).
Related commands: nncal, tvchannels
tatts [#1 #2]Sets the target sampler/GTP levels to #1 for IF1 and #2 for
IF2. After these targets have been altered, the command atts should
be issued. Issuing tatts without arguments will return the current
targets. The default sampler level target is 20.0 for each IF.
Related commands: atts, calband, userms, usegtp
tvchan[nels] [fn] [# #] ...Set the ’TV’ channels. The channels in the tvchannels range
are averaged together to produce the quantities that VIS displays,
that ASSISTANCE checks, that CATAG uses for pointing corrections,
that contribute to the correlator GTP values, etc. If the IF to alter
is specified with fn (where n is one of the available IFs), then
only 1 set of tvchannels should be specified. Example:
tvchannels f1 500 1600
This will set the IF1 tvchannels to cover the range 500-1600. If the IF
is not specified, then 1 set of tvchannels should be specified for each
available IF. Example:
tvchannels 500 1600 900 1400
This will set the IF1 tvchannels to cover the range 500-1600, and the IF2 tvchannels to cover the range 900-1400. If there are more IFs than this, the command will produce an error message in the log panel, but the tvchannels will still be changed for the specified IFs.
The default tvchannels usually
cover the entire central half of the band (ie. channels 513-1537). To reset
the tvchannels to this, substitute the channel specification with
def[ault].
To determine what the tvchannels
are currently set to, either look at the status panel, or issue this command
without arguments.
Related commands: delavg
usegtpThis command causes the correlator to display the gated total power (GTP)
in the tvchannels range for each input (antenna, IF, polarisation) in
the “Sampler Levels” tab in the data panel.
Related commands: userms, tatts, atts
usermsThis command causes the correlator to display the voltage RMS value from the
samplers on each input (antenna, IF, polarisation) in the “Sampler Levels”
tab in the data panel.
Related commands: usegtp, tatts, atts
Users Guide last modified on 2011-04-27 15:49:06